Hoods Elica LOL IX/A/60

Namopi scorei
65
Price from:
329.00

Inverter drive

Silent, efficient and long lasting. Performance and durability of a device is to a large extend depend on an engine. Inverter drives are quieter, more reliable and durable compared to standard engines but also more expensive. Silent, efficient and long lasting. Performance and durability of a device is to a large extend depend on an engine. Inverter drives are... More

Intensive mode

Quickly removes unpleasant smells. Quickly removes unpleasant smells.  More

Automatic intensive reverts

If intensive mode is set, a hood returns to normal mode automatically in 5-6 minutes. It is convenient as you don’t have to remember to switch to normal mode.If intensive mode is set, a hood returns to normal mode automatically in 5-6 minutes. It is convenient as you don’t have to remember to... More

Automatic switch off

It’s useful when you what a hood to switch off automatically when required. Usually different time limits are used for different operation speeds.It’s useful when you what a hood to switch off automatically when required. Usually different time limits are used for different operation... More

Filter saturation indicator

The function reminds when steel filters should be cleaned or carbon filters changed. It’s useful as you don’t have to remember yourself when to clean or change filters.The function reminds when steel filters should be cleaned or carbon filters changed. It’s useful as you don’t have to remember yourself... More

Light type

LED lighting is nicer and more economic than standard.LED lighting is nicer and more economic than standard. More
LED

Adjustable intensity lighting

It allows to regulate intensity of the light. It allows to regulate intensity of the light.  More

Re-circulating

When carbon filters are installed, the function enables to return cleaned air back to the room. Sucked weather is cleaned in the grease or active carbon filter and returned to the kitchen. It’s useful when there is no possibility to connect a hood to the ventilation system but filters should be changed regularly according to manufacturer recommendations.When carbon filters are installed, the function enables to return cleaned air back to the room. Sucked weather is cleaned in the grease or... More

Automatic functions

A hood has temperature sensor which activates the device when a temperature near the hood reaches certain level or it has air quality sensor which activates a hood and automatically sets its operating parameters depending on air quality and switches it off when air quality is back to normal.A hood has temperature sensor which activates the device when a temperature near the hood reaches certain level or it has air quality... More

Flexible timer

Operation time could be set flexibly.Operation time could be set flexibly. More

Control type

Sensor

Display with clock

Number of intensive speed's levels

Some hoods have several intensive mode levels.Some hoods have several intensive mode levels. More
1

Extraction levels

Usually hoods have 3 normal mode speed levels. Please note that hood noise is lowest when it operates at a minimum speed level.Usually hoods have 3 normal mode speed levels. Please note that hood noise is lowest when it operates at a minimum speed level. More
3

Price per Namopi point, €

It helps to compare different models. If you chose few models you like, lower Price per NAMOPI Point is likely to indicate better value for money.It helps to compare different models. If you chose few models you like, lower Price per NAMOPI Point is likely to indicate better value for... More
5.06

Energy class

Higher energy class indicates lower water and energy consumption and less environment pollution but usually also means higher price. Energy class is indicated from A+++ (top effectiveness, least consumption of energy) to G (least effectiveness, highest energy consumption level).Higher energy class indicates lower water and energy consumption and less environment pollution but usually also means higher price. Energy... More
B

Country of origin

Poland

Fluid dynamic efficiency class

Indicates the efficiency with which the hood is able to extract vapours generated through cooking (A maximum - G minimum efficiency).Indicates the efficiency with which the hood is able to extract vapours generated through cooking (A maximum - G minimum efficiency). More
B

Lighting efficiency class

Indicates the efficiency with which the hood is able to illuminate the cooker hob (A maximum - G minimum efficiency).Indicates the efficiency with which the hood is able to illuminate the cooker hob (A maximum - G minimum efficiency). More
A

Grease filtering efficiency class

Indicates the efficiency with which the hood filters grease generated through cooking (A maximum - G minimum efficiency).Indicates the efficiency with which the hood filters grease generated through cooking (A maximum - G minimum efficiency). More
C

Mounting type

Wall Mounted

Height, cm

58-109

Width, cm

59.8

Depth, cm

45

Duct out

A hood is connected to the ventilation system. Sucked weather is cleaned in the grease cleaning filter and removed through the ventilation system. It’s important that hood vent matches ventilation system vent.A hood is connected to the ventilation system. Sucked weather is cleaned in the grease cleaning filter and removed through the ventilation... More

Minimum Air Flow in normal use, m³/h

Usually more hood power means higher cost. Therefore, a hood should be selected for a specific room. A hood set at minimum air flow mode should change air in the room 6 times an hour. Please note that every additional air ventilation pipe meter or 90 degrees turn decreases hood power. In such circumstances, Correction Ratio 1.3 should be used to calculate required hood power. For a 10 sq. m. and 2.5 meters height kitchen min hood power should be calculated as follows: 10 x 2.5 x 6 x 1.3 (Correction Ratio) = 195 m³. If a kitchen is connected to other rooms, more powerful hood may be required.Usually more hood power means higher cost. Therefore, a hood should be selected for a specific room. A hood set at minimum air flow mode... More
272

Maximum Air Flow in normal use, m³/h

Usually more hood power means higher cost. Therefore, a hood should be selected for a specific room. A hood set at maximum air flow mode should change air in the room 12 times an hour. Please note that every additional air ventilation pipe meter or 90 degrees turn decreases hood power. In such circumstances, Correction Ratio 1.3 should be used to calculate required hood power. For a 10 sq. m. and 2.5 meters height kitchen max hood power should be calculated as follows: 10 x 2.5 x 12 x 1.3 (Correction Ratio) = 390 m³. If a kitchen is connected to other rooms, more powerful hood may be required.Usually more hood power means higher cost. Therefore, a hood should be selected for a specific room. A hood set at maximum air flow mode... More
515

Air Flow at intensive setting, m³/h

669

Annual energy consumption, kWh

It shows average annual energy consumption. Factual energy consumption depends on individual device usage patterns.It shows average annual energy consumption. Factual energy consumption depends on individual device usage patterns. More
66

Noise level at minimum speed, dB

Hoods are usually used in a kitchen. Therefore, it is very important that their noise would not disturb. Noise level is measured in decibel (dB). Hood noise level at minimum speed normally ranges from 35 dB to 75 dB. Smaller the dB figure, more silent is device. For indication, 30 dB associates with leave rustle sound, 40 dB with whispering, 50 dB with normal speaking, 60 dB – louder speaking and 70 dB – loud speaking.Hoods are usually used in a kitchen. Therefore, it is very important that their noise would not disturb. Noise level is measured in decibel... More
49

Noise level at maximum speed, dB

Hoods are usually used in a kitchen. Therefore, it is very important that their noise would not disturb. Noise level is measured in decibel (dB). Hood maximum noise level during normal use ranges from 50 dB to 75 dB. Smaller the dB figure, more silent is device. For indication, 30 dB associates with leave rustle sound, 40 dB with whispering, 50 dB with normal speaking, 60 dB – louder speaking and 70 dB – loud speaking.Hoods are usually used in a kitchen. Therefore, it is very important that their noise would not disturb. Noise level is measured in decibel... More
66

Noise level at intensive mode, db

70

Colour

Stainless steel

WHERE TO BUY

TOP ratings in your mailbox

Compare